- Browse Valves
- CFG 101
- Valves
Valves
From simple single-head showers to combinations of both tub and shower, valves are a critical component of any shower application.
This section is designed to provide a basic overview of all of CFG's shower valve options and help identify which valve you are working with, as well as to provide troubleshooting information.
Product Offering
Valves
Anatomy of a Valve
Every shower has a valve that acts like an engine – shifting flow, regulating temperature and driving performance, and there are many options for design, functionality and operation suited to different applications.
The valve is placed behind the wall and connects directly to hot and cold water lines to regulate flow and temperature. CFG Dimension valves have a thin profile to fit within 2-by-3-inch wall studs. Most CFG valves are available in a variety of ½-inch connection types, including IPS/CC, PEX and CPVC.
A cartridge inserted into the valve connects to the external trim handles to control the mixture of hot and cold water and flow through the faucet based on the handle position. With this design, most leak issues can be solved simply by replacing the cartridge.
Select valves are available configured for shower-only or pre-fitted for tub/shower applications.
With a CFG Dimension valve, you can be certain of safety, comfort and reliability since our valves meet applicable pressure-balancing safety codes, eliminating worry about hot or cold water surges. Plus, you can rely on our quality construction and dependable operation since each valve is backed by our most comprehensive 10-Year Multi-Family Warranty.
Terminology
Pressure-Balancing
All CFG Dimension valves are pressure-balancing to protect users from "shower shock" due to a sudden change in either hot- or cold-water pressure elsewhere in the plumbing system (i.e., toilet flush) by adjusting the flow of water to maintain a consistent water temperature. CFG Dimension valves feature a self-contained pressure-balancing spool located upstream from the water shutoff to minimize sticking. Water temperature remains +/- 3-degrees F, regardless of demand elsewhere in the system.
Easy Switch: With CFG Dimension valves, you can upgrade from cycling to volume control without replacing the valve. Instead, simply exchange cartridges and trim.
Cycling Valve
- Cycling valves feature point-of-use reversibility – great for back-to-back multi-family applications
- Handle rotates from cold to hot to control water temperature
- Does not provide volume control
Volume Control
- Volume control valves allow users to control both the temperature and the amount of water flowing out of the faucet
- Handle pulls out to adjust flow and rotates to control temperature
Browse by Model
Model: 45311/45317
Dimension Cycling Valve with Male IPS/CC or Female IPS Connections With Shut-Off Stops
HOW IT IS USED:
Upgrade to a volume control valve with ceramic cartridge replacement.
INSTALLATION:
- Fitted with Male IPS/CC (45311) or Female IPS (45317) connections; no sweating required
- Back-to-back install capable
BENEFITS:
- Built-in Shut-Off stops and check valves resolve potential clogging issues
- Adjustable temperature limit stops
Model: 45312/45318
Dimension Cycling Valve with Male IPC/CC or Female IPS Connections Without Shut-Off Stops
HOW IT IS USED:
Shower and tub applications. Upgrade to a volume control valve with ceramic cartridge replacement.
INSTALLATION:
- Fitted with Male IPS/CC (45312) or Female IPS (45318) connections; no sweating required
- Back-to-back install capable
BENEFITS:
- Built-in check valves resolve potential clogging issues
- Adjustable temperature limit stops
Model: 45319
Dimension Cycling Valve with Male IPS/CC Outlet and PEX Inlet and Shower Outlet Connections Without Shut-Off Stops
HOW IT IS USED:
Shower and tub applications. Upgrade to a volume control valve with ceramic cartridge replacement.
INSTALLATION:
- Fitted with PEX connections; no sweating required
- Back-to-back install capable
BENEFITS:
- Built-in check valves resolve potential clogging issues
- Adjustable temperature limit stops
Model: 45313
Dimension Cycling Valve with Copper Outlet Tube and PEX Inlet and Shower Outlet Connections Without Shut-Off Stops
HOW IT IS USED:
Shower and tub applications; includes copper outlet pipe for easy tub kit install. Upgrade to a volume control valve with ceramic cartridge replacement.
INSTALLATION:
- Fitted with PEX connections; no sweating required
BENEFITS:
- 8-by-7-inch copper tube outlet
- Built-in check valves resolve potential clogging issues
- Adjustable temperature limit stops
Model: 45320
Dimension Cycling Valve with Male IPS/CC Outlet and PEX Inlet and Shower Outlet Connections With Shut-Off Stops
HOW IT IS USED:
Shower and tub applications. Upgrade to a volume control valve with ceramic cartridge replacement.
INSTALLATION:
- Fitted with PEX connections; no sweating required
BENEFITS:
- Built-in Shut-Off stops and check valves resolve potential clogging issues
- Adjustable temperature limit stops
Model: 45321
Dimension Cycling Valve with CPVC Connections With Shut-Off Stops
HOW IT IS USED:
Shower and tub applications. Upgrade to a volume control valve with ceramic cartridge replacement.
INSTALLATION:
- Fitted with CPVC connections; no sweating required
- Back-to-back install capable
BENEFITS:
- Built-in Shut-Off stops and check valves resolve potential clogging issues
- Adjustable temperature limit stops
Model: 45511
Dimension Volume Control Valve with Male IPS/CC Connections With Shut-Off Stops
HOW IT IS USED:
Shower and tub applications. Same body as 45311 with 40068 ceramic volume control cartridge for temperature and flow control.
INSTALLATION:
- Fitted with Male IPS/CC connections; no sweating required
BENEFITS:
- Built-in Shut-Off stops and check valves resolve potential clogging issues
- Adjustable temperature limit stops
Model: 45514
Dimension Volume Control Valve with Brass Outlet Plug and PEX Inlets and Shower Outlet Connections Without Shut-Off Stops
HOW IT IS USED:
Shower applications. Same body as 45319 with 40068 ceramic volume control cartridge for temperature and flow control.
INSTALLATION:
- Fitted with PEX connections; no sweating required
BENEFITS:
- Built-in check valves resolve potential clogging issues
- Adjustable temperature limit stops
- Brass plug-in tub outlet
Model: 45513
Dimension Cycling Valve with Copper Outlet Tube and PEX Inlets and Shower Outlet Connections Without Shut-Off Stops
HOW IT IS USED:
Tub/shower applications; includes copper outlet pipe for easy tub kit install. Same body as 45313 with 40068 ceramic volume control cartridge for temperature and flow control.
INSTALLATION:
- Fitted with PEX connections; no sweating required
BENEFITS:
- 8-by-7-inch copper tube outlet
- Built-in check valves resolve potential clogging issues
- Adjustable temperature limit stops